Labels: monitor | reckoner | sky
OCR: Thermal Performance Thermal Comfort In both cases the temperature at the center of glass 57 and can handle 63% relative humidity without condensation on the glass The coldest point on the wood frame due to the conductive metal spacer at the edge of the insulating glass The warmest point 70 which Is the same as the room temperature The coldest point on the aluminum frame IS and condensation may start . appear at 15% relative humidity It's not surprising that the condensation and frost shown on the previous slides occurred under those environmental conditions This needs to be considered when de tailing the materials around the window to minimize moisture damage to adiacent finishes like drywall returns and plastic laminate sills This slide illustrates why total window performance important L ...